Welcome: Haining Dongben Measurement and Control Technology Co., Ltd.
Language: Chinese ∷  English

Controller

  • XMT-J800 Eight-Channel intelligent Temperature Controller&control temperature PID-Infrared temperature sensor
  • XMT-J800 Eight-Channel intelligent Temperature Controller&control temperature PID-Infrared temperature sensor
XMT-J800 Eight-Channel intelligent Temperature Controller&control temperature PID-Infrared temperature sensorXMT-J800 Eight-Channel intelligent Temperature Controller&control temperature PID-Infrared temperature sensor

XMT-J800 Eight-Channel intelligent Temperature Controller&control temperature PID-Infrared temperature sensor

  • Product description: Application: Pressure, and temperature measurement & controller-Infrared temperature sensor
  • INQUIRY

Model: IRT-XMT-J800

Name: IRT-XMT-J800 Eight-Channel intelligent Temperature Controller


Place of Origin: Zhejiang, China (Mainland)

Brand Name: IRT-XMT

Model Number: Eight-Channel intelligent Temperature Controller&control temperature P

Usage: Industrial

Theory: Temperature Controller

Accuracy: 0.5

Temperature range: -200~1600C

Input(can be selected): K.E.J.S.PT100.CU50

Precision: 0.5%FS ± 0.1additional cold end compensating deviation±1

Power supply: 85~240VAC, 50/60Hz

Modularization Design: Customization

Size: 80*160

Power Consumption: Less than 5W

Packaging: Standard Export Pack

Color: Grey or Black

Approval: CE

Installation hole: 152*76


DOB-XMT-J800 Eight-Channel intelligent Temperature Controller&control temperature PID

Features:

IRT-XMT-J800 Eight-Channel intelligent Temperature Controller&control temperature PID is a new meter to meet the market needs.  The meter is controlled by single chip microcomputer, every channel setting value and some parameters can be set up independently. It has the advantages of small volume, low power consumption, simple operation, easy control, stable operation, reliable, economical characteristics. It is widely used in the temperature automatic control systems of machinery,chemical,ceramics,light industrial,metallurgy,petrifaction and heat treatment, and so on

Specifications:

Input(can be selected):   CU50(-50~150),PT100(-80~600),K(-30~999),

E(-30~700),J(-30~900),T(199~400)

Sampling cycle:  0.5S

Measurement deviation:  ≤±0.5%F·S±1B   Cold end compensating deviation: ≤±2.0°C

Control cycle:  relay output 2~120S , other is 2S

Relay output contact capacity:  AC220V/5A (resistance load) or AC220V/0.3A (perceptual load)

Alarm relay contact output :  AC220V/1A(resistance load)

Driving solid relay signal output :  driving electric current15mA, voltage9V.

Power supply :  AC85V~242V, 50/60Hz

Working condition :  temperature 0~50.0°C, relative humidity85%RH, without corrode and strong electric radiation.

Remarks:  If need the instrumention manusls Pls send me a mail, I will send to you asap!

Model significance:

XMT -  J   8   _   8   _    _

1    2   3   4        5   6

1.Meter faceplate and Installation dimension(mm):160×80×130;  152×76;

2.Design serial number:Eight channel independent control meter, PID and ON/OFF control can optional;

3. Alarm:0:no set alarm; 1:one alarm ( alarm mode optional);

4.Input signal: 8: Free exchange of the input signal

5. Main control mode: space: relay normally-open normally-closed contact output;

A:Single phase zero trigger control; G:Solid state relay control output

6. Suffix:K:with 485 or RS232 Communication module interface;

WT:With an external printer module interface